§ 60.42. Standard for particulate matter (PM).
422 words·~2 min read·
/us/cfr/t40/s§ 60.42·A research copy — for the controlling text, always check the official state or federal source. Not legal advice.
(a)Except as provided under paragraphs (b), (c), (d), and
(e)of this section, on and after the date on which the performance test required to be conducted by § 60.8 is completed, no owner or operator subject to the provisions of this subpart shall cause to be discharged into the atmosphere from any affected facility any gases that:
(1)Contain PM in excess of 43 nanograms per joule (ng/J) heat input (0.10 lb/MMBtu) derived from fossil fuel or fossil fuel and wood residue.
(2)Exhibit greater than 20 percent opacity except for one six-minute period per hour of not more than 27 percent opacity. (b)(1) On or after December 28, 1979, no owner or operator shall cause to be discharged into the atmosphere from the Southwestern Public Service Company's Harrington Station #1, in Amarillo, TX, any gases which exhibit greater than 35 percent opacity, except that a maximum or 42 percent opacity shall be permitted for not more than 6 minutes in any hour.
(2)Interstate Power Company shall not cause to be discharged into the atmosphere from its Lansing Station Unit No. 4 in Lansing, IA, any gases which exhibit greater than 32 percent opacity, except that a maximum of 39 percent opacity shall be permitted for not more than six minutes in any hour.
(c)As an alternate to meeting the requirements of paragraph
(a)of this section, an owner or operator that elects to install, calibrate, maintain, and operate a continuous emissions monitoring systems
(CEMS)for measuring PM emissions can petition the Administrator (in writing) to comply with § 60.42Da(a) of subpart Da of this part. If the Administrator grants the petition, the source will from then on (unless the unit is modified or reconstructed in the future) have to comply with the requirements in § 60.42Da(a) of subpart Da of this part.
(d)An owner or operator of an affected facility that combusts only natural gas is exempt from the PM and opacity standards specified in paragraph
(a)of this section.
(e)An owner or operator of an affected facility that combusts only gaseous or liquid fossil fuel (excluding residual oil) with potential SO2 emissions rates of 26 ng/J (0.060 lb/MMBtu) or less and that does not use post-combustion technology to reduce emissions of SO2 or PM is exempt from the PM standards specified in paragraph
(a)of this section. [60 FR 65415, Dec. 19, 1995, as amended at 76 FR 3522, Jan. 20, 2011; 74 FR 5077, Jan. 28, 2009; 77 FR 9447, Feb. 16, 2012]
Connections33 cite this
Cited by 33 sections · top 16
register
- Proposed RulesFinal action
- NoticesProposed rule
- Proposed RulesFinal rule
- NoticesNotice of availability
- Rules and RegulationsFinal rule; notice of final action on reconsideration
- NoticesNotice of availability
- Rules and RegulationsFinal rule
- Rules and RegulationsProposed rule
- Rules and RegulationsFinal rule; notice of final action on reconsideration
- NoticesFinal rule
- NoticesNotice of availability
- Rules and RegulationsProposed rule
- NoticesProposed rule
- Rules and RegulationsProposed rules; notice of public hearing
- Proposed RulesProposed rule
- Rules and RegulationsProposed rule
Citation graph
cites case law
§ 60.42
Standard for particulate matter (PM).
Fed. Reg.×33
Cites 0Cited by 33 across 1 source